Revision 1c9cf5c...
Go back to digest for 27th April 2014Bug Fixes in KDE Base
Kai Uwe Broulik committed changes in [kde-workspace/KDE/4.11] /generic/applets/batterymonitor/contents:
Prevent popup from closing when changing brightness battery monitor is hidden in system tray
Touching the plasmoid status causes the popup to close. This patch does not touch the status
as long as the popup is open and defers that to when the popup closes.
REVIEW: 117533
FIXED-IN: 4.11.9
File Changes
Modified 2 files
- /generic/applets/batterymonitor/contents
- plasma/code/logic.js
- plasma/ui/batterymonitor.qml
2 files changed in total