Kai Uwe Broulik committed changes in [kde-workspace/KDE/4.11] /generic/applets/batterymonitor/contents:

Prevent popup from closing when changing brightness battery monitor is hidden in system tray

Touching the plasmoid status causes the popup to close. This patch does not touch the status
as long as the popup is open and defers that to when the popup closes.

REVIEW: 117533

FIXED-IN: 4.11.9

File Changes

Modified 2 files
  • /generic/applets/batterymonitor/contents
  •   plasma/code/logic.js
  •   plasma/ui/batterymonitor.qml
2 files changed in total